Your privacy is very important for us. When you visit our website, please agree to the use of all cookies. For more information about the processing of personal data, please go to Privacy Policy

  • HI15KTHcemian11.png
  • HI15KTHxiliezhengmian11.png
  • HI15KTHdibu1.png
Hybrid Inverters

HI-15~20K-TH

  • 15~20kw
  • Three Phase
  • High Voltage

Technical Parameters

Inhenergy HI-15-20K-TH SERIES inverter, ranging from 15-20kw, It is compatible with high voltage Li-Ion batteries ranging from 150 to 600V. Support generator interface to meet a variety of usage needs. Support up to six inverters connected in parallel, with a maximum output power of 120kw.


  • gongsijieshaoyoushishuju6-910.png

    Core Value
    Future proof battery ready
    Low initial investment

  • fuyong1-313.png

    High Yields
    DC/AC ratio up to 1.5
    Max. efficiency 98%

  • fuyong2-494.png

    Safety and Reliability
    Type II SPD on DC side
    Support export limitation

  • 10ms-995.png

    Leading Functions
    UPS function, 10ms transition
    Smart Meter Integrated

  • dianchi-202.png

    System Flexibility
    Support lithium and lead-acid battery
    Whole home backup

  • gongsijieshaoyoushishujuTop3-166.png

    Support GEN

Technical Data
Technical DataHI-15K-THHI-20K-TH
PV String Input Data

Max. DC input power23000W30000W
Max. DC input voltage1 100V1 100V
Nominal input voltage600V600V
MPPT working voltage range180V-1000V 180V-1000V 
Number of independent  MPPT / strings per MPPT2/1+12/1+1
MPPT max. current30A/30A30A/30A
Start-up voltage/Min.operating voltage200V/180V200V/180V
AC Output/Input Data (On-grid)

Nominal output apparent power15000W20000W
Max. output apparent power16500VA22000VA
Nominal output voltage400V±20%400V±20%
Nominal ouput freqency50Hz, 60Hz/±5Hz50Hz, 60Hz/±5Hz
Max. output current24A32A
Power factor-0.8~+0.8(adjustable)-0.8~+0.8(adjustable)
THDi<3%(Nominal Output)<3%(Nominal Output)
Grid system pattern3L+N+PE3L+N+PE
Max.apparent power from utility grid30000VA40000VA
Max.AC current from utility grid48A64A
Back-up Output Data (UPS)

Peak output apparent power16500VA,10s22000VA,10s
Nominal output apparent power15000VA20000VA
Nominal output voltage400V±20%400V±20%
Nominal ouput frequency50Hz/60Hz50Hz/60Hz
Output THDV<3%<3%
Automatic switch time<20ms<20ms
Battery Input Data

Battery typeLi-IonLi-Ion
Battery voltage range150V-600V150V-600V
Max. charging/discharging current50A50A
Battery capacity(AH)50-200050-2000
Charging strategy for Li-Ion batterySelf-adaption to BMSSelf-adaption to BMS
Efficiency

Max. effificiency98%98%
Europe effificiency97.5%97.5%
Max. battery to load effificiency98%98%
Protection

Anti islanding protectionYesYes
Insulation impedance protectionYesYes
RCD detectionYesYes
PV reverse polarity protectionYesYes
Output over voltage protectionYesYes
Output over current protectionYesYes
General Data

Dimensions(W/L/H)in mm403/465/285403/465/285
Weight23kg23kg
Operation temperature range-25℃~+60℃-25℃~+60℃
Heat dissipation modeSmart coolingSmart cooling
IP ClassIP 65IP 65
Maximum altitude4000m4000m
Self-Consumption night<3w<3w
TopologyTransformerlessTransformerless
Features

LCD displayYesYes
Communication interfaceWiFi/4G/USB/CAN/RS485WiFi/4G/USB/CAN/RS485
StandardsEN 62109-1/EN 62109-2/EN 62477-1/IEC 61000-6-1/IEC 61000-6-3/CEI 0-21/ UNE 217001/UNE 217002/VDE 0126/IEC 61727/IEC 62116/EN 50549-1/G98/ G99/AS 4777.2EN 62109-1/EN 62109-2/EN 62477-1/IEC 61000-6-1/IEC 61000-6-3/CEI 0-21/ UNE 217001/UNE 217002/VDE 0126/IEC 61727/IEC 62116/EN 50549-1/G98/ G99/AS 4777.2